Components and Sizing

You are here

Components

  Description
Exchangers
    Evaporator heat exchanger ceramic or graphite
    Condenser ceramic or graphite
Tanks
    Separator tank high temp thermoplastic or lined steel
    Rectifier tank high temp thermoplastic or lined steel
    Recovered acid collection tank lower portion of Rectifier tank
    Recovered water tank thermoplastic vacuum tank
Pumps
    Spent acid feed pump air operated diaphragm
    Separator pump low NPSH centrifugal
    Vacuum pump plastic centrifugal
    Recovered acid pump plastic centrifugal
Other Components
    Microprocessor control center HMI & Allen-Bradley PLC
    Auto-valves/automation corrosion proof
    Framework epoxy coated
    Acid-in filter station PVC / polypro

Optional Equipment, not included: boiler, cooling tower, and cooling tower pump.

 

Sizing

HCl Recovery System - 3 renderings

System Sizes Available
Model size 1MT 2MT 5MT 10MT 15MT 25MT 50MT 75MT 100MT 150MT
Capacity, metric tonnes/day 1 2 5 10 15 25 50 75 100 150

 

We use proprietary software to size a system for you based upon the information submitted in a Request for Quote.  Typically, your quote can be completed within a few days. 
 
Customizations available:
  • Remote monitoring via office computer or a smartphone app
  • Remote login assistance by Beta's engineers to help with troubleshooting
  • System dimensions to fit your floorspace—easy to visualize with 3D model
  • Setpoints for recovered acid concentration and temperature
  • Automatic fresh acid additions
  • Plumbing lines directly to system or using storage tanks for the waste and recovered acid
  • Insulating pipes in cold climates; cooling for the control panel in hot climates