Home | Products | Plant Design | Spare Parts | Locations | About Us | Chinese

         
Up
Metric
US standard
Energy Requirements (US standard units)
 

Models:  Small through Mid-size

Energy Requirements 2KL 5KL 10KL 15KL 25KL 50KL
Boiler
Boiler size BHP 7 20 40 60 100 200
Steam capacity #/hr 241.5 690 1380 2070 3450 6900
Actual usage KBtu/hr 234.3 669.4 1338.9 2008.3 3347.2 6694.4
Cooling Tower
Cooling tower ton 15 25 40 75 125 250
  joules 1.90E+08 3.16E+08 5.06E+08 9.49E+08 1.58E+09 3.16E+09
Pumps & Motors
Tower pump h.p. 2 2 2 3 5 10
Tower/Condensor h.p. 1 1.5 2 3 3 5
Evap (Separator) pump h.p. 3 3 5 5 7.5 10
Feed pump h.p. 0 0 0 0 1.5 3
Total energy (pumps) KWh 4.5 4.8 6.7 8.2 12.7 20.9
               
Compressed Air
Feed Pump SCFM 4.0 4.0 4.0 8.0 0.0 0.0
Rectifier Pump SCFM 2.0 2.0 2.0 2.0 4.0 4.0
Recovered Acid SCFM 2.0 2.0 2.0 4.0 4.0 6.0
Concentrate SCFM 2.0 2.0 2.0 4.0 4.0 6.0
Total comp. Air SCFM 10.0 10.0 10.0 18.0 12.0 16.0

 

 

  Models:  Large

Energy Requirements 75KL 100KL 150KL
Boiler      
Boiler size 300 400 600
Steam capacity 10350 13800 20700
Actual usage 10041.6 13388.8 20083.2
Cooling Tower      
Cooling tower 400 500 750
  5.06E+09 6.32E+09 9.49E+09
Pumps & Motors      
Tower pump 15 15 15
Tower/Condensor 10 10 15
Evap (Separator) pump 15 20 20
Feed pump 7.5 7.5 7.5
Total energy (pumps) 35.4 39.2 42.9
       
Compressed Air      
Feed Pump 0.0 0.0 0.0
Rectifier Pump 8.0 8.0 8.0
Recovered Acid 10.0 10.0 14.0
Concentrate 7.0 8.0 10.0
Total comp. Air 25.0 26.0 32.0

 

         
© Beta Control Systems, Inc.  All rights reserved.

last updated April, 2003